The 
ARM
 subsystem selects the number of scanning cycles (1 through
32767) for each 
INITiate
 command.
ARM
:COUNt <
number
> MIN | MAX
:COUNt? [MIN | MAX]
:COUNt
ARM:COUNt <
number
> MIN | MAX
  allows scanning cycles to occur a
multiple of times (1 to 32767) with one 
INITiate
 command when
INITiate:CONTinuous OFF | 0
 is set.  
MIN
 sets 1 cycle and 
MAX
 sets 32,767
cycles.
Parameters
Parameter Name
Parameter Type
Range of Values
Default Value
number
numeric
1 - 32767 | MIN | MAX
1
Comments
Number of Scans: Use only numeric values between 1 and 32767
for the number of scanning cycles (default is 1). 
Related Commands: 
ABORt
INITiate:IMMediate
*RST Condition: 
ARM:COUNt 1
Example
Setting Ten Scanning Cycles
This example sets a Microwave Switch for 10 scans of channels 00 through
02.  When the scan sequence completes, channels 00 through 02 (switches
00 through 02) are closed.
ARM:COUN 10
Set 10 scans per INIT command.
SCAN   (@100:102)
Scan channels 00-02.