gohastings.com Hastings Entertainment Oxygen Equipment HFM-I-401 Manual De Usuario

Descargar
Página de 35
 
 
- 13 - 
Insure flow 
connections 
are leak tight
Check mounting and 
mechanical 
installation including 
flow direction
Verify power 
connections on analog 
terminal strip 
+ Vsup → pin 1
- Vsup → pin 2 
Verify output and other 
connections on analog 
terminal strip 
(See Section 2.?) 
Check digital M12 
connector and/or cable 
Using Digital 
Communications
Complete
Digital 
Communications
Interface
Check/Set IP 
address
Complete
Check Model # 
and Software 
Revision
S1
Check Zero 
Offset
S16
Check Full 
Scale Voltage
S11
Check Serial 
Number
S68
Check Current 
Flow Value
F
Check Model # 
and Software 
Revision
*[address]S1
Check Zero 
Offset
*[address]S16
Check Full 
Scale Voltage
*[address]S11
Check Serial 
Number
*[address]S68
Check Current 
Flow Value
*[address]F
Complete
Complete
Yes
No
RS-232
RS-485
Ethernet