Galil DMC-1700 Manual De Usuario

Descargar
Página de 253
DMC-1700/1800 
Chapter 6  Programming Motion  •  103 
 
Command Summary - Coordinated Motion Sequence 
COMMAND DESCRIPTION. 
VM m,n 
Specifies the axes for the planar motion where m and n represent the planar axes and p is 
the tangent axis. 
VP m,n 
Return coordinate of last point, where m=X,Y,Z or W. 
CR r,
Θ, ±ΔΘ 
Specifies arc segment where r is the radius, 
Θ is the starting angle and ΔΘ is the travel 
angle.  Positive direction is CCW. 
VS s,t 
Specify vector speed or feedrate of sequence. 
VA s,t 
Specify vector acceleration along the sequence. 
VD s,t 
Specify vector deceleration along the sequence. 
VR s,t 
Specify vector speed ratio 
BGST 
Begin motion sequence, S or T 
CSST 
Clear sequence, S or T 
AV s,t 
Trippoint for After Relative Vector distance. 
AMST 
Holds execution of next command until Motion Sequence is complete. 
TN m,n 
Tangent scale and offset. 
ES m,n 
Ellipse scale factor. 
VT s,t 
S curve smoothing constant for coordinated moves 
LM? 
Return number of available spaces for linear and circular segments in DMC-1700/1800 
sequence buffer.  Zero means buffer is full.  512 means buffer is empty. 
CAS or CAT 
Specifies which coordinate system is to be active (S or T) 
Operand Summary - Coordinated Motion Sequence 
OPERAND DESCRIPTION 
_VPM 
The absolute coordinate of the axes at the last intersection along the sequence. 
_AV Distance 
traveled. 
_LM  
Number of available spaces for linear and circular segments in DMC-1700/1800 sequence 
buffer.  Zero means buffer is full.  512 means buffer is empty. 
_CS 
Segment counter - Number of the segment in the sequence, starting at zero. 
_VE 
Vector length of coordinated move sequence. 
 
When AV is used as an operand, _AV returns the distance traveled along the sequence
The operands _VPX and _VPY can be used to return the coordinates of the last point specified along the path. 
Example: 
Traverse the path shown in Fig. 6.3.  Feedrate is 20000 counts/sec.  Plane of motion is XY 
VM XY 
Specify motion plane 
VS 20000 
Specify vector speed 
VA 1000000 
Specify vector acceleration 
VD 1000000 
Specify vector deceleration 
VP -4000,0 
Segment AB