Galil DMC-1700 Manual De Usuario

Descargar
Página de 253
142 • Chapter 7 Application Programming DMC-1700/1800 
DMC-1700 and DMC-1800 Event Triggers 
Command Function 
AM X Y Z W or S 
(A B C D E F G H) 
Halts program execution until motion is complete on 
the specified axes or motion sequence(s).  AM with no 
parameter tests for motion complete on all axes.  This 
command is useful for separating motion sequences in 
a program. 
AD X or Y or Z or W 
(A or B or C or D or E or F or G or H) 
 
Halts program execution until position command has 
reached the specified relative distance from the start of 
the move.  Only one axis may be specified at a time. 
AR X or Y or Z or W 
(A or B or C or D or E or F or G or H) 
 
Halts program execution until after specified distance 
from the last AR or AD command has elapsed.  Only 
one axis may be specified at a time. 
AP X or Y or Z or W 
(A or B or C or D or E or F or G or H) 
Halts program execution until after absolute position 
occurs.  Only one axis may be specified at a time. 
MF X or Y or Z or W  
(A or B or C or D or E or F or G or H)  
 
Halt program execution until after forward  motion 
reached absolute position.  Only one axis  may be 
specified.  If position is already past  the point, then 
MF will trip immediately.  Will function on geared 
axis or aux. inputs. 
MR X or Y or Z or W  
(A or B or C or D or E or F or G or H)  
 
Halt program execution until after reverse  motion 
reached absolute position.  Only one axis  may be 
specified.  If position is already past  the point, then 
MR will trip immediately.  Will function on geared 
axis or aux. inputs. 
MC X or Y or Z or W 
 (A or B or C or D or E or F or G or H)  
 
Halt program execution until after the motion  profile 
has been completed and the encoder has  entered or 
passed the specified position.  TW  x,y,z,w sets 
timeout to declare an error if not  in position.  If 
timeout occurs, then the  trippoint will clear and the 
stopcode will be  set to 99.  An application program 
will jump to  label #MCTIME. 
AI +/- n 
Halts program execution until after specified  input is 
at specified logic level.  n specifies  input line.  
Positive is high logic level,  negative is low level.  n=1 
through 8 for DMC-1X10, 1X20, 1X30, 1X40.    n=1 
through 24 for DMC-1X50, 1X60, 1X70, 1X80.   n=1 
through 80 for DMC-17X8.   
AS X Y Z W S 
(A B C D E F G H) 
Halts program execution until specified axis has 
reached its slew speed. 
AT +/-n 
Halts program execution until n msec from reference 
time.  AT 0 sets reference.  AT n waits n msec from 
reference.  AT -n waits n msec from reference and sets 
new reference after elapsed time. 
AV n 
Halts program execution until specified distance along 
a coordinated path has occurred. 
WT n 
Halts program execution until specified time in msec 
has elapsed.