Alvarion BREEZENET BU-DS.11 Manual De Usuario

Descargar
Página de 92
Installation 
 
 
 
2-15 
Verifying Correct Operation 
The following sections describe how to ensure that the units are correctly installed 
and functioning properly. 
Verifying Correct Operation of the Indoor Unit 
To verify proper operation, check the LED indicators located on the top panel of the 
indoor unit as shown in Figure 
 
 
2-2. 
Name Description  Functionality 
POWER 
Power indication 
Orange - 48VDC is present on the Radio RJ45 port. 
Off - No power is supplied to the Radio RJ45 port. 
LINK 
Self Test and 
Ethernet Link 
indication 
The LINK LED indicates end-to-end connection between the 
outdoor unit and the Ethernet connection to the indoor unit. 
Off – No Ethernet connectivity has been detected between the 
outdoor unit and the device connected to the indoor unit. 
Green– Self-test passed and Ethernet connection is confirmed by the 
outdoor unit (Ethernet integrity check passed). 
Table 
 
2-2: Indoor Unit LEDs 
Verifying Correct Operation of the Outdoor 
Unit 
To verify proper operation, check the LED indicators located on the bottom panel of 
the outdoor unit. 
Name Description 
Functionality 
WLAN 
 
Wireless Link 
Indicator 
The green LED is updated every second. It will be turned on if 
at least one data packet (excluding beacons) was transmitted 
during the last second. Thus, it will stay on continuously when 
there is high traffic. In lower traffic rates it will blink-where the 
blinking rate is slower when there is less wireless traffic. 
DC Power 
 
Self Test and Power 
indication 
Green – Power is available and self-test passed.