SPECIAL APPLICATION
400-0384-003
28
Example 2:  Adjust Brightness
Now that the plasma is in adjustment mode, 
various settings may be changed. Set the 
brightness to a value of 100 by sending the 
following commands directly to the internal bus:
[SENDBS<%02%2A%2A>]
[SENDBS<BRT150%03>]
NOTE:
The [SENDBS] command can only 
send 16 characters at a time. Break 
the command into smaller sections if 
necessary, or store the entire 
command in a memory location.
Example 3: Select Inputs
Select between Input 1 and Input 2. This time, 
use commands that are stored in memory. 
First program memory locations 10 and 20 with 
the input select commands. Memory location 10 
will store the IN1 command and location 20 will 
store the IN2 command. Send the IN1 and IN2 
commands along with the STX, ID and ETX 
portions of the command by sending the 
following:
[WRM10=%02%2A%2A;1]
Write location 10.
[WRM10=IN1%03;0]
Append location 10.
[WRM20=%02%2A%2A;1]
Write location 20.
[WRM20=IN2%03;0] 
Append location 20.
Second, recall the commands from memory and 
send them to the internal bus using the following 
commands:
[OUTPDPM10]
Select Input 1
[OUTPDPM20]
Select Input 2
7.5 PIONEER PLASMA COMMANDS
A detailed listing of RS-232 commands is available 
in the PDP-504CMX Command Protocol Manual 
available on the Pioneer Electronics website. 
Please see the following links.
Pioneer website:
Pioneer Manual:
w w w . p i o n e e r e l e c t r o n i c s . c o m / p i o / p e
/ i m a g e s / p o r t a l / c i t _ 3 4 2 4 / 1 6 4 1 5 1 8 0 3
P D P 5 0 4 C M X _ R S 2 3 2 - C P M . p d f
Some of the commands and features in the guide 
will only be available depending on the model and 
options of the Pioneer display.
TROUBLESHOOTING GUIDE
8
We have carefully tested and have found no 
problems in the supplied PE1005.  However, we 
would like to offer suggestions for the following:
8.1  THERE IS NO COMMUNICATION
Cause 1:
There is a setup problem.
Solution:
Check the communication software 
and verify the PE1005 is connected 
to the correct communication port 
and that the software is connected. 
If there is still no response, see 
Cause 2.
Cause 2:
The connection is wrong.
Solution:
Verify the RS-232 cabling is correct. 
The  RS-232 transmit and receive 
pins are pins 14 and 16 of the 25-pin 
HD connector. If there is still no 
response, please call ALTINEX at 
(714)-990-2300.
8.2  RELAYS DO NOT WORK
Cause 1:
The cabling is incorrect.
Solution:
See  DIAGRAM  4:  25-PIN HD 
DETAILS for connection details. If 
the cabling is good and the relays 
still do not switch, see Cause 2.
Cause 2:
The correct relay does not switch.
Solution:
There are four internal relays, 1 
through 4. Turn on all the relays by 
sending the command [WRRL*=1].  
If some of the relays are open, 
please call ALTINEX
at 
(714)-990-2300.