OPERATION 
INTRAC-305 
 
 
Page  26 
INTRAC-305 MANUAL  -  Issue 3.2                                    ©2011 Advantech Wireless 
 
DIAGNOSTICS ON / DIAGNOSTICS OFF 
 
1
2
3
4
5
6
Current Mode     Tracking
Control State    Local
Beac Freq      11.452000 GHz
Beac Level    -10.05 dB
El   Angle     25.37
Az   Angle    210.50
Pol  Angle     27.4   
Standby
Home
Models
Test
Port-1
Diags
System 
Setup
Function
Press EN to accept selection
Next 
Field
  
Beacon Frequncy
  Edit Satellite Table
  Soft Limits
  Extended Azimuth Setup
> Diagnostics On
        
<
 
  Diagnostics Off
  Beacon Threshold
  
puts the antenna control system into
STANDBY mode and skips to the HOME
menu
skips to the Home (root) menu
skips to the Models menu
selects whether ‘Angles’ or ‘Diagnostics’
appear on Test Port 1
skips to the System Setup menu
moves the highlight box to the next field
in the current menu
 
 
 
 
Path 
 
HOME - FUNCTION - MENU KEY 6 (x5 for ON)  
 
 
 
 
(x6 for OFF) - ENTER 
 
 
 
or 
From Models or System Setup 
 
 
 
 
CONFIG - MENU KEY 6 (x5 or 6) - ENTER 
 
 
 
Description 
 
Diagnostics On & Off are used to route the INTRAC 
diagnostic data to the Remote Control port.   
 
 
 
 
Use Menu Key 6 to step the highlight bar to the ON or OFF 
line and press ENTER to set. 
 
 
 
Note 
This facility enables one PC to be used as both the remote 
control terminal and the diagnostics receiving terminal.  
However it cannot do both at the same time. 
 
 
 
 
WHEN IT IS REQUIRED TO CONTROL THE INTRAC FROM 
THE REMOTE TERMINAL DIAGNOSTICS MUST BE 
SWITCHED OFF.