Advantech INTRAC-305 Manual De Usuario

Descargar
Página de 96
 
INTRAC-305  
OPERATION 
 
© 2011 Advantech Wireless
 
INTRAC-305 MANUAL  -  Issue 3.2 
Page  25 
 
3
 
X2 SETUP 
 
X2 resolvers have a 1:2
gearbox on the input shaft
to provide extra resolution.
This screen allows the user
to resolve a +/- 180º
ambiguity in the displayed
main axes angles.
1
2
3
4
5
6
puts the antenna control system into
STANDBY mode and skips to the HOME
menu
skips to the Home (root) menu
sets the offset for the X2 resolver
clears the offset for the X2 resolver
(not used)
(not used)
Current Mode     Tracking
Control State    Local
Beac Freq      11.452000 GHz
Beac Level    -10.05     dB
El   Angle     25.37
Az   Angle    210.50
Pol  Angle     27.4   
Standby
Home
Set
Offset
Function
Press EN to accept selection
Clear
Offset
X2 RESOLVER SETUP
 
 
 
 
Path 
 
HOME - FUNCTION - MENU KEY 6 (x4) - ENTER 
 
 
 
or 
From Models or System Setup :-   
 
 
 
 
CONFIG - MENU KEY 6 (x4) - ENTER 
 
 
 
Note 
This funct
ion is only available if the “Resolver Type” in 
System Setup - 
Fitted Options has been set to “EG-01 Fitted”. 
 
 
 
If the “Extended Az” in System Setup - Fitted Options has 
been set to “Fitted” this line of the Configuration menu reads 
“Extended Azimuth Setup”.  (see previous page) 
 
 
 
Description 
 
The EG-01 resolvers have a 1:2 gear ratio between the input 
shaft and the angle data output.  This is in order to achieve 
higher resolution.  However it means that the output moves 
through 720
 for 360
 of input rotation.  Thus in Azimuth the 
INTRAC seeks to initially resolve this 180
 ambiguity.