Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
265
53-1002373-02
Installing a Brocade NetIron XMR 16000 router
4
5. Tighten the screws to secure the router.
NOTE
For better grounding of the router to the rack, attach the router using star washers. You can also use 
star washers with single-hole grounding lugs to prevent rotation of the lug.
6. Repeat 
 through 
 to mount each router in the rack.
Installing Brocade NetIron XMR 16000 modules
The Brocade NetIron XMR 16000 router ships with the required switch fabric modules installed.
The procedure in this section applies to all modules. The sequence for installing multiple modules 
is important to ensure proper fit. For the Brocade NetIron XMR 16000 router, start with the lowest 
row, and move upwards, installing modules from left to right.
For instructions about installing 2x100GbE interface modules, refer to 
DANGER
The intra-building port or ports of the equipment or subassembly is suitable for connection to 
intra-building or unexposed wiring or cabling only. The intra-building port or ports of the 
equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the 
outside plant (OSP) or its wiring. These interfaces are designed for use as intra-building 
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 5) and require 
isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient 
protection in order to connect these interfaces metallically to OSP wiring.
NOTE
Brocade NetIron XMR modules are dedicated, which means that you must install them in Brocade 
NetIron XMR routers only. For example, if you install a Brocade NetIron XMR module in another 
Brocade router or install a module intended for another Brocade router in the Brocade NetIron XMR 
router, the router and module will not function properly.
Although management modules are designed to be hot-swappable, you must upgrade the software 
on all interface modules and management modules to the appropriate software release before 
installing them. For more information on the appropriate software release, refer to the Hardware 
Installation Notes that shipped with the management module. 
For information about how to disable and re-enable power to interface modules, see 
 identifies the slots where you install modules. Identification markings are located at the 
base of each slot.
TABLE 42
Brocade NetIron XMR 16000 module installation
Module
Slot number
Management modules
Active module – M1 (upper).
Redundant module – M2 (lower).