5. TEMPERING OF HOT WATER
Installation of an automatic mixing valve will
lengthen the delivery of the available hot water by mixing
some cold water with the hot. This prevents excessive
and possibly scalding hot water. Higher temperature hot
water is possible by piping the hot water from the heater
prior to entering the mixing valve. The mixing valve
should be “trapped” by installing it below the cold water
inlet to heater to prevent lime formation in the valve.
6. FLUSHING THE BOILER
All water contains some sediment which settles on
6. FLUSHING THE BOILER
All water contains some sediment which settles on
the inside of the coil. Consequently, the heater should
be periodically backwashed. This is accomplished by
installing hose bibs as illustrated and allowing water at
city pressure to run into hosebib A, through the heater,
and out hosebib B until the discharge is clear. The tees
in which the hosebibs are located should be the same
size as heater connections to minimize pressure drop.
7. HARD WATER
May be applicable to some city and particularly well
7. HARD WATER
May be applicable to some city and particularly well
water. Have your water analyzed by a qualified water
treatment specialist to determine if a water softener,
conditioner or filtration is required. Treated water will
ensure longer tankless heater life and performance
and is also beneficial to all the piping and fixtures in the
building.