5. TEMPERING OF HOT WATER 
Installation of an automatic mixing valve will 
lengthen the delivery of the available hot water by mixing 
some cold water with the hot. This prevents excessive 
and possibly scalding hot water. Higher temperature hot 
water is possible by piping the hot water from the heater 
prior to entering the mixing valve. The mixing valve 
should be “trapped” by installing it below the cold water 
inlet to heater to prevent lime formation in the valve.
6.  FLUSHING THE BOILER
  
All water contains some sediment which settles on 
the inside of the coil. Consequently, the heater should 
be periodically backwashed. This is accomplished by 
installing hose bibs as illustrated and allowing water at 
city pressure to run into hosebib A, through the heater, 
and out hosebib B until the discharge is clear. The tees 
in which the hosebibs are located should be the same 
size as heater connections to minimize pressure drop. 
7.  HARD WATER
  May be applicable to some city and particularly well 
water. Have your water analyzed by a qualified water 
treatment specialist to determine if a water softener, 
conditioner or filtration is required. Treated water will 
ensure longer tankless heater life and performance 
and is also beneficial to all the piping and fixtures in the 
building.