GE RAG61 Instruccion De Instalación

Descargar
Página de 60
25
LINTEL
Cord Set Connected
WALL SECTION – DETAILED SIDE VIEW
FRAME 
AND 
BRICK VENEER INSTALLATION
Sub-Base Connected
STEEL LINTEL
CAULK*
RAB71   13-3/4”
RAB77   13-7/8”
20-7/8”   (RAB71)
21”        
 (RAB77)
MOUNTING SCREWS
BY INSTALLER
RAB71   16”
RAB77   16-1/4”
OUTDOOR
GRILLE
2” MIN.
WALL CASE
ROOM
CABINET
1/4”
MIN.
WALL RECEPTACLE
(BY OTHERS)
POWER SUPPLY
CONDUIT
*Caulk around perimeter of wall case all four sides
where it joins the building.
RAG60                  1/4”
RAG61, 62, 63   1-3/8”
RAG64, 65, 66   1-3/8”
RAB71   13-3/4”
RAB77   13-7/8”
20-7/8”   (RAB71)
21”        
 (RAB77)
MOUNTING SCREWS
BY INSTALLER
RAB71   16”
RAB77   16-1/4”
OUTDOOR
GRILLE
2” MIN.
WALL CASE
ROOM
CABINET
SIDE CHANNEL
SUB-BASE
(RAK204)
FINISHED FLOOR
OR TOP OF
CARPET
POWER SUPPLY CONDUIT
(ALTERNATE ENTRY)
Caulk around
perimeter of wall
case all four
sides where it
joins the building.
3”  MIN.
5”  MAX.
1/4”
3-11/16”
1-5/16”
FINISHED FLOOR
OR TOP OF
CARPET