Furuno 10n Manual De Usuario

Descargar
Página de 33
 11 
Thru-hull mount water temperature sensor T-02MSB, T-03MSB 
Select a suitable mounting location considering the following points: 
 
•  Select a mid-boat flat position. The sensor does not have to be installed perfectly 
perpendicular. However, the location should not be such that the transducer may be 
damaged when the boat is dry-docked. 
•  Locate away from equipment which gives off heat. 
•  Locate away from drain pipes. 
•  Select a location where vibration is minimal. 
Sensor
cable
Locknut
Coat with
sealant.
Plate thickness
within 25 mm
Coat with
sealant.
φ
21 mm
φ
25 mm
Washer
Gasket
Locknut
Locknut
Washer
Gasket
Holder Guide
Sensor Holder
T-02MSB
T-03MSB
Mounting procedure
1. Drill a hole of 21 mm in diameter in 
    the mounting location.
2. Pass the sensor cable through the
    hole.
3. Pass gasket, washer and locknut
    onto cable in that order.
4. Coat the sensor flange with high
    quality sealant and then fasten the
    sensor with the locknut. 
    (Torque: max. 59N·m)
5. Launch the boat to check for water
    leakage around the sensor.
Mounting procedure
1. Drill a hole of 25 mm in diameter in the mounting 
    location.
2. Coat holder guide with high quality sealant, and
    pass gasket, washer and locknut onto holder
   guide in that order and then tighten the locknut.
3. Set the sensor holder to the holder guide from
    inside the boat and then tighten the locknut. 
4. Launch the boat to check for water leakage 
    around the sensor.
 
Figure 1-15 Assembling thru-hull water temperature sensor T-02MSB, T-03MSB