MICROMASTER Applications Handbook
7.3.3
Key Parameter Details
Note.
Careful selection of the inputs is needed to ensure the correct combination of
forward and reverse frequencies is possible.
Careful selection of the inputs is needed to ensure the correct combination of
forward and reverse frequencies is possible.
Table 7-3
Key Parameters. Lift Door Operation
Number Value Meaning
P1000 3
Fixed
Frequencies
selected
P0003
3
Allows all parameters to be adjusted and set
P1001
- 5
Fixed Frequency 1. Setting the following parameters allows the complex
selection of fixed frequencies, forward and reverse, to be selected using
only the two microswitch inputs and the open/close signal
selection of fixed frequencies, forward and reverse, to be selected using
only the two microswitch inputs and the open/close signal
P1002
-6
Fixed Frequency 2
P1003
- 15
Fixed Frequency 3
P1004
5
Fixed Frequency 4
P1005
+25
Fixed Frequency 5
P1006
+2
Fixed Frequency 6
P1007
+10
Fixed Frequency 7
P0701-3
17
Binary selection of fixed frequencies
P0300-
P0311
P0311
***
Settings to suit motor