Emerson 3812 Manuel D’Utilisation

Page de 138
36
Use of appropriate safety engineered swivel hoist rings in meter end flanges
Section 2: Mechanical installation
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual
May 2015
3-9000-765 Rev H
9.
Direct mount option: NEVER allow the slings to contact the electronics enclosure. 
Damage to the enclosure may occur. Use a spreader bar with the slings to prevent 
contact with the electronics enclosure and the base enclosure (
). If the 
slings do come in contact with the electronic enclosure then remove the four bolts 
holding the enclosure to its base and temporarily remove the head from the meter 
during the lifting operation. You will need to unplug the cable on the Acquisition 
Module. Two screws hold this cable in place. Once the lifting operation is complete, 
reattach and secure the electronics cable on the Acquisition Module, return the 
electronics enclosure to its original position, replace the bolts, and secure the enclosure 
in place.
Lifting the meter with the upper enclosure installed but without the bolts installed, may 
cause the electronics to fall and cause personal injury or equipment damage.
Figure 2-10  Sling contacting electronics enclosure