MoistAir MA0600 Manuel D’Utilisation

Page de 8
 
 
 
 
How Your Humidifier Works 
 
Your new humidifier is designed to satisfy home humidity requirements through the 
principle of evaporation of water in the air.  
Once the filter becomes saturated, air is drawn in, passes through the filter and 
moisture is absorbed into the air. All evaporation occurs in the humidifier so any 
residue remains in the filter. This natural process of evaporation virtually eliminates 
white dust. 
 
 
 
 
 
 
 
 
 
 
 
Once removed from its carton, 
remove all packing materials.  
Verify the filter is properly installed 
(See page 10). 
Step 1.  Location 
 
 
 
 
 
 
 
 
 
 
 
 
 
CAUTION: To reduce the risk 
of injury, fire or damage to 
humidifier, use only cleaners 
specifically recommended for 
humidifiers. Never use 
flammable, combustible or 
poisonous materials to clean 
your humidifier. To reduce the 
risk of scalds and damage to 
humidifier, never put hot water 
in humidifier. 
WARNING: For your own safety, do not use humidifier if any parts are 
damaged or missing. 
Selecting a Location 
Place humidifier on a flat level surface; 
take extra care in leveling when placing 
the unit on carpet. Position the humidifier 
where the most humidity is needed or 
where the most air will be circulated 
throughout the house such as near a cold 
air return. 
Getting Your 
Humidifier Up  
and Running  
Moist air (humidity) produced will 
disperse into the whole house, but 
the area closest to the unit will 
have the highest humidity. If the 
unit is positioned close to a 
window, condensation may form 
on the window pane. If this occurs 
the unit should be repositioned in 
another location.
 
 
 
13 
 Troubleshooting 
Trouble Probable 
Cause 
Remedy 
Digital display not 
illuminated. 
•  No Power 
Power button has not been 
depressed. 
•  Check 120 volt power source. 
•  Press power button once to turn 
on. 
Fan not operating (digital 
display is illuminated). 
•  ROOM humidity level is not 3% or 
more below SET humidity level. 
•  Reservoir is empty. 
•  Raise SET humidity level if 
desired. 
•  Increase fan speed. 
•  Fill humidifier with water. 
Fan running 
continuously. 
•  SET humidity level is 65%. 
•  ROOM humidity level has not 
reached 1% or more above SET 
humidity level. 
•  A Set humidity percentage of 65% 
operates fan continuously. Adjust 
SET level between 25%-60%.  
•  Continue to run until desired 
humidity level is achieved. This 
may take up to 48 hours initially. 
Poor evaporation of 
water. 
•  CHECK FILTER message 
flashing. 
•  Mineral buildup on filter. 
•  Change to a fresh new filter. 
•  NOTE: Local water purity varies 
from area to area. 
Bottle empties 
completely. 
•   This is normal for  
  initial filling. 
•  Refill bottle for maximum run time. 
Bottle continues to empty 
after complete filling. 
•  Air is entering water bottle. 
•  Check for leak in water bottle. 
Bottle not emptying. 
•  Spring Valve Assembly damaged 
or missing post in bottom of base. 
•  Base full of water. 
•  Check orientation of bottle. 
Reposition so that fill valve on 
bottom of bottle is depressed by 
post in bottom of base. 
The base will hold the contents of 
water bottle (1.25 gallons). 
Continue to run humidifier to 
deplete water from base. 
Display blinks or fan 
moves slightly when  
humidifier is plugged in. 
•  Normal 
•  No action required. 
Fan operating slower 
than speed registered on 
digital display 
•  Humidifier in “DRY OUT MODE”. 
•  Humidifier automatically switches 
fan to (LOW) F1 when “F” and 
alternating room humidity is 
displayed. 
Humidifier not shutting off 
during “DRY OUT MODE” 
•  Filter not dry. 
•  During “DRY OUT MODE” the 
humidifier will continue to run on 
“LOW” speed as required for up to 
2 hours or until the filter is 
completely dry. 
Alternating “F” and room 
humidity displayed.  
•  Reservoir is empty. 
• Fill humidifier with water. 
Alternating “CF” and 
room humidity displayed. 
•  Filter may be dirty. 
•  Replace filter. 
•  Unplug unit for 30 seconds and 
replug in to clear.