check the following items during installation prior to 
lighting the multisided burner:
•  Check air shutter for correct setting.
o  NAT gas - The air shutter setting must be1/8" (3.2mm) 
for VFSUR(18,24,30)-2.
o  LP gas - The air shutter setting must be  Full Open 
for VFSUR(18,24,30)-2
NOTe: Orifice shield removed for photo clarity.
•  Check all carryover ports for blockage from the ceramic 
media
 
o  If there is blockage, use a small pointed tool to move 
the ceramic media away from the carryover port.
•  For best results when lighting the burner, have the  ad-
justable flame knob to the HI position, then adjust to a 
lower setting after the burner has ignited.
•  When first lighting the pilot on the burner, it takes ap-
proximately 60 to 75 seconds to fully heat and energize 
the thermopile. Once the thermopile is energized, turn 
on the gas valve and light the burner.
AIR SHUTTER 1/8” (3.2 mm) OPEN
AIR SHUTTER FULL OPEN
BuRNeR INSTRucTIoNS