Nordyne SERIES M1B Manuel D’Utilisation

Page de 40
20
STARTUP AND ADJUSTMENTS
PLEASE READ ALL SAFETY INFORMATION 
BEFORE LIGHTING THE FURNACE
Lighting Instructions - Standing Pilot Models.
1. Set the thermostat to the lowest setting.
2. Turn off all electric power to the appliance.
3. Remove the furnace door.
4. Push in and move the gas control lever to the 
OFF positon (Figure 30). DO NOT FORCE
5. Wait 10 minutes to clear out any gas. If you smell 
gas, STOP! and read the Safety Information. 
If you don’t smell gas, proceed to step 6.
6. Find pilot - follow metal pilot tube from gas 
control valve. Open hinged fi re observation 
door. The pilot is found at the end of the pilot 
tube just left of the pilot shield (Figure 31).
7. Lightly depress the gas control lever and move 
it to the ON position. Release and move the 
lever to the PILOT position.
8. Move the control lever to SET and hold. 
Immediately light the pilot with a match. 
Continue to hold the control lever for about one 
(1) minute after the pilot is lit. NOTE: The pilot 
fl ame is adjustable by turning the adjustment 
screw located on the gas valve with a small 
screwdriver. See Figure 29.
9. Release the lever and it will spring back to the 
PILOT position. NOTE: Pilot should remain lit. 
If it goes out, repeat steps 4 through 8 above. If 
the lever does not spring back when released, 
immediately call your service technician or gas 
supplier. If the pilot will not stay lit after several 
tries, move the gas control lever to OFF and 
call your service technician or gas supplier.
10. Move the gas control lever to ON.
11. Turn on all electric power to the furnace.
 WARNING:
Before placing the furnace in 
service, it must be checked to 
ensure it is equipped for the type 
of gas being used. The burner fl ame 
must be observed and adjusted 
if necessary. Failure to observe 
this caution may result in unsafe 
operation, explosion and/or fi re, or 
asphyxiation. See the Gas Supply 
and Combustion Air sections.
•  The fi rst lighting of the furnace after any 
home setup must be performed by a 
qualifi ed service technician.
•  If this appliance has a pilot that must be lit by 
hand, follow these instructions exactly.
•  BEFORE LIGHTING: Smell all around the 
furnace for gas and next to the fl oor. Some 
gas is heavier than air and may settle on the 
fl oor.
•  Use only your hand to push in the gas control 
lever. Never use tools. If the lever will not push in 
by hand, don’t try to repair it. Force or attempted 
repair may result in a fi re or explosion. Call a 
qualifi ed service technician.
•  Do not use this furnace if any part has been 
under water. Immediately call a service 
technician to inspect the furnace and to replace 
any part of the gas valve or control system 
which has been under water.
FIRE OR EXPLOSION HAZARD
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; 
do not use any phone in your 
building.
• Leave the building immediately.
• Immediately call your gas supplier 
from a neighbors phone. Follow the 
gas suppliers instructions.
• If you cannot reach your gas 
supplier, call the fi re department.
 WARNING:
Figure 31. Lighting The Furnace
PILOT
BRACKET
Gas Control Lever
Figure 30. Standing Pilot Valve
Pilot Position
Set Position