Check  your  building  codes  for  any  special 
requirements for locating equipment shutoff 
valve to fireplaces.
Apply pipe joint sealant lightly to male NPT 
threads. This will prevent excess sealant from 
going into pipe. Excess sealant in pipe could 
result in clogged fireplace valves.
FirePLAce inStALLAtiOn
Continued
Figure 19 - Gas Connection
Equipment Shutoff Valve 
with 1/8" NPT Tap*
3" Minimum
Approved 
Flexible 
Gas Line
Cap  Pipe 
Tee
 
Joint 
Nipple
Sediment Trap/
Drip Leg
Natural - From 
Gas Meter (5.5" 
W.C. to 10.5" W.C. 
Pressure)
Propane/LP From 
External Regulator 
(11" W.C. to 14" 
W.C. Pressure)
* The equipment shutoff valve may be sup-
plied with the appliance or you can purchase 
it from your retailer.
Figure 20 - Connecting Incoming Gas Line to Flex Gas Line
Red Surface Indicates For 
Propane/LP Use Only
Pilot Adjustment
Inlet Pressure Tap
Outlet Pressure Tap
  WARNING:  Use  pipe  joint 
sealant that is resistant to liquid 
petroleum (LP) gas.
We recommend that you install a sediment 
trap/drip leg in supply line as shown in Figure 
19. Locate sediment trap/drip leg where it is 
within reach for cleaning. Install in piping sys-
tem between fuel supply and fireplace. Locate 
sediment trap/drip leg where trapped matter 
is not likely to freeze. A sediment trap traps 
moisture and contaminants. This keeps them 
from going into fireplace gas controls. If sedi-
ment trap/drip leg is not installed or is installed 
wrong, fireplace may not run properly.
CONNECTING FIREpLACE TO GAS 
SUppLY
Installation Items Needed
•  5/16" hex socket wrench or nut-driver
•  sealant (resistant to propane/LP gas, not 
provided)
1.  Route  flexible  gas  line  (provided  by  in-
staller)  from  equipment  shutoff  valve  to 
fireplace. Route flexible gas supply line 
through one of the access holes on side 
of fireplace.
2.  Attach flexible gas line from gas supply to 
control valve (see Figure 20).
3.  Check all gas connections for leaks. See 
Checking Gas Connections, page 18.
IN
PILOT
IN
OUT
VENT
TH
TP
TH TP
Gas Shutoff 
Valve
Flexible 
Gas Line 
Do NOT 
Kink
1/2" NPT 
Incoming 
Gas Line
Note:
1) Wire connections not 
shown for clarity
2) * 1/8" NPT Plugged 
Tapping