FirePLAce inStALLAtiOn
CHECK GAS TYPE
Use proper gas type for the fireplace unit you 
are installing. If you have conflicting gas types, 
do not install fireplace. See retailer where you 
purchased the fireplace for proper fireplace 
according to your gas type.
INSTALLING GAS pIpING TO 
FIREpLACE LOCATION
  WARNING:  A  qualified 
service  person  must  connect 
fireplace to gas supply. Follow 
all local codes.
  CAUTION:  For  propane/LP 
units, never connect fireplace di-
rectly to the propane/LP supply. 
This heater requires an external 
regulator (not supplied). Install 
the external regulator between 
the  fireplace  and  propane/LP 
supply.
  WARNING:  For  natural 
gas, never connect fireplace to 
private  (non-utility)  gas  wells. 
This  gas  is  commonly  known 
as wellhead gas.
Installation Items Needed
Before  installing  fireplace,  make  sure  you 
have the items listed below.
•  external regulator (supplied by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection *
•  sediment trap
•  tee joint
•  pipe wrench
•  approved flexible gas line with gas connec-
tor (if allowed by local codes)
* An equipment shutoff valve with 1/8" NPT 
tap is an acceptable alternative to test gauge 
connection. Purchase the equipment shutoff 
valve from your retailer.
For propane/LP connection only, the installer 
must supply an external regulator. The exter-
nal regulator will reduce incoming gas pres-
sure. You must reduce incoming gas pressure 
to between 11" and 14" of w.c. pressure. If 
you  do  not  reduce  incoming  gas  pressure, 
fireplace regulator damage could occur. Install 
external regulator with the vent pointing down 
as shown in Figure 18. Pointing the vent down 
protects it from freezing rain or sleet.
  CAUTION:  Use  only  new, 
black  iron  or  steel  pipe.  Inter-
nally-tinned copper tubing may 
be used in certain areas. Check 
your  local  codes.  Use  pipe  of 
1/2" diameter or greater to allow 
proper gas volume to fireplace. 
If pipe is too small, undue loss 
of volume will occur.
Installation must include an equipment shutoff 
valve, union and plugged 1/8" NPT tap. Locate 
NPT tap within reach for test gauge hook up. 
NPT tap must be upstream from fireplace (see 
Figure 19, page 17).
IMPORTANT: Install main gas valve (equip-
ment shutoff valve) in an accessible location. 
The main gas valve is for turning on or shutting 
off the gas to the appliance.
Figure 18 - External Regulator with Vent 
Pointing Down (Propane/LP Only)
Propane/LP 
Supply Tank
External Regulator 
with Vent Pointing 
Down