Nilfisk-Advance America GD 930S2 Manuel D’Utilisation

Page de 32
7
1.  To open
a) Loosen the two snap lockings by pulling them  outwards 
b) Lift the cover from the container.
2.  Dust bag 
Fit the opening on the dust bag over the air inlet. Press the 
membrane over the flanged edge on the inlet. Secure with 
the lock washer. Use only original dust bags.
3.  Hose connection
Push the hose coupling all the way in and turn clockwise. 
4.  Wand assembly
 Standard:  Fit  the  sections  together  and  twist  to  lock  in 
place. 
Telescopic: Push  down the catch and then adjust the length. 
Max.950mm,min.630mm.  
5.  Tools
The accessories shown in the pictures may vary from model 
to model.
a-b)Combination nozzle   
Adjust the nozzle according to the requirements of the floor 
you are cleaning. Work with the brush on hard floors and 
without it on soft floors.
c)   Universal nozzle
for both hard floors and carpets.
d)Crevice nozzle 
Use  to  clean  furniture,  radiators  and  others  hard-to-reach 
places.
e)Small combi-nozzle:
The small combi-nozzle combines a dusting brush for furni-
ture, picture frames, mouldings etc. with a fold-out nozzle for 
cleaning curtains, furniture and other soft surfaces. The clip 
on the hose handle holds the nozzle when it is not in use.
6.  Suction control
The suction control in the hose handle lets you regulate the 
air-flow to prevent the nozzles from fastening to the surfaces 
you are vacuum cleaning. 
7.  Start/Stop
a) Foot-operated on/off switch. 
b)On  the  S2  version  a  separate  switch  is  provided  to 
change the motor speed .
c)Plug-in point for powered carpet nozzle. 
Power  is  supplied  to  the  socket  when  the  machine  is 
switched on.
8.  Warning!
Never  attempt  to  vacuum  liquid,  glass  fragments  or 
ashes!
Wet surfaces can expose the operator to possible 
electrical shock.
9.  Filter
The filters are located inside the lid. To reach them lift out 
the filter holder
(a). The standard filter(b) and fine filter (c) 
should  be  inspected  at  regular  intervals,e.g.  when  you 
change  dust  bags,  and  replace  if  necessary.Instead  of 
these two filters you can fit a micro filter of HEPA-quality 
(e)
wich traps 99,99% of all particles larger than 0,3 microns. 
The machine is also fitted with a backup filter 
(d) located 
above the motor. This filter should also be inspected and 
replaced  if necessary. 
IMPORTANT!
The  GD  930/S2  is  equipped  with  a  specially  
designed cable, which if damaged, must be replaced by 
a cable of the same type. These cables are avaible at 
authorized service shops and must be installed by trained 
personnel.
The GD 930/S2 is equipped with a thermal cut-out to protect 
the motor and other vital machine parts from overheating. 
Should the machine cut out, you will have to wait at least 
5-10 minutes for it to automatically reset. While you are 
waiting, switch the machine off and unplug it, then check 
the hose, dust bag and filters to be sure that nothing is 
blocking the flow of air through the machine.
NB!
Remove the plug from the socket before performing service 
or maintenance.
The symbol            on the product or on its packing indicates that this 
product may not be treated as household waste. Instead it shall be 
handed over to the applicable collection point for the recycling of elec-
trical and electronic equipment. By ensuring this product is disposed 
of correctly, you will help prevent potential negative consequences for 
the environment and human health, which could otherwise be caused 
by inappropriate waste handling of this product.  
For more detailed information about recycling of this product, please 
contact your local city office, your household waste disposal service or  
the shop where you purchased the product.
822 9393 000 Instruction for use GD 930 EU.indd   7
2008-06-26   13:06:12