GE C11 Manuel D’Utilisation

Page de 98
 
- 83 -
 
Item 
Specifications 
Remarks 
Installation 
location 
 Indoor use only. Do not install a dusty location(Degree of pollution: 2) or 
expose to direct sunlight, corrosive gases, flammable gases. 
 
Ambient  
temperature 
 -10 to +50°C  (+14 to +122°F ) 
 
Ambient  
humidity 
 5 to 95%RH ( No condensation ) 
 
Altitude 
 3300 Feet (1000 m)  or less 
 
Vibration 
 3 mm:  
2 to less than 9 Hz 
 9.8m/s
2
:   9 to less than 20 Hz 
 2m/s
2
:  
20 to less than 55 Hz 
 1m/s
2
55 to less than 200 Hz 
 
Storage tem-
perature 
 -25 to +65°C  
 
Environment
 
Storage humid-
ity 
 5 to 95% RH (No condensation) 
 
Higher  
harmonics 
current 
suppression 
 Terminal for connecting power-factor correcting DC reactor (DCR) is pro-
vided as standard. 
P1, P(+) terminal 
Charging sup-
pression resis-
tor 
 Charging suppression resistor is built-in for all drive unit. 
 
Others
 
Cooling fan 
ON/OFF con-
trol 
 Cooling fan can be automatically stopped when drive is stopped.