Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-952
ISDN-SGR (ISDN-PRI Signaling Group) 
9
administered for the signaling group. If there are problems with the ISDN-PRI 
Secondary Signaling Channel port (ISDN-LNK), also investigate the UDS1 circuit 
pack (UDS1-BD).
Layer 2 Status Test (#647)
The Layer 2 Status Test checks the layer 2 status of the ISDN-PRI Signaling 
Channel (D-channel). This test will fail if there is a hardware failure or a facility 
problem, or if the primary and secondary ISDN-PRI D-channels are not 
administered correctly.
The Primary and Secondary Signaling Link Hardware tests (test 637 and 639) 
and the Remote Layer 3 Query test (test 637) will detect most problems caused 
by hardware failures or incorrect administration. However, the Layer 3 test (test 
637) cannot detect end-to-end transmission problems with the Standby 
D-channel since Layer 3 messages are not sent on the standby channel.
For G3r, the SYS-LINK Maintenance Object reports Layer 2 ISDN-PRI D-channel 
problems and for G3i/s/vs, the PI-LINK Maintenance Object reports Layer 2 
ISDN-PRI D-channel problems (if the D-channel is connected to the Processor 
Interface circuit pack). However, for G3i, the PI-LINK Maintenance Object does 
not monitor the Layer 2 status of the ISDN-PRI D-channel when the D-channel is 
connected to the Packet Control circuit pack for the ISDN-PRI over PACCON 
feature. The Layer 2 Query test is provided to detect D-Channel Layer 2 failures 
Table 9-364.
TEST #639 Secondary Signaling Link Hardware Check 
Error 
Code
Test Result
Description/ Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1132
ABORT
The Secondary D-Channel is not administered for this Signaling Group. This 
is a NORMAL ABORT. Only a Primary D-Channel must be administered for a 
Signaling Group.
8
FAIL
There is a problem with the TN464C/D UDS1 Interface circuit pack or the 
ISDN-PRI Secondary Signaling Channel (D-Channel). No ISDN trunk or PRI 
endpoint calls can be made until the problem is resolved.
1. Consult the procedures for the UDS1 TN464C/D Circuit Pack 
(UDS1-BD) and the ISDN-PRI Signaling Channel (ISDN-LNK).
PASS
The basic physical connectivity of the Signaling Group’s Secondary 
D-channel is intact and functional. Try this test repeatedly to ensure the link 
is up and to uncover any transitory problems.
Continued on next page