Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-954
ISDN-SGR (ISDN-PRI Signaling Group) 
9
3
FAIL
Both the primary and secondary are down.
1. Examine the results of the Primary and SecondarySignaling Link Hardware 
Tests (#636 and #639) and follow recommendations provided there.
2. If tests #636 and #639 pass, the Layer 2 Query test may still fail if the 
Signaling Channel at the far end has not been administered correctly or if 
the Signaling Channel has been busied out. Verify that the Primary and 
Secondary Signaling Channel (D-channel) at the far end has been 
administered correctly. Verify that the DS1 port used for the Primary and 
Secondary D-channels has not been busied out at the far end.
PASS
The Primary Signaling Channel is up and, if administered the Secondary 
Channel is up.
Table 9-365.
TEST #647 Layer 2 Status Query Test — Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page