Lucent Technologies Release 7 Manuel D’Utilisation

Page de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-953
ISDN-SGR (ISDN-PRI Signaling Group) 
9
and generate an associated Warning alarm independent of the hardware 
configuration used for the D-channels.
Table 9-365.
TEST #647 Layer 2 Status Query Test
Error 
Code
Test 
Result
Description/ Recommendation
1132
ABORT
Internal system error:
The port location for the primary ISDN-PRI D-channel is not known. This 
condition should not be possible since an administered DS1 circuit pack must 
be specified when a Signaling Group is administered:
1. Retry the command at one minute intervals a maximum of five times.
1134
ABORT
Internal system error:
The associated DS1 circuit pack is not administered. This condition should not 
be possible since an administered DS1 circuit pack must be specified when a 
Signaling Group is administered.
1. Retry the command at one minute intervals a maximum of three times.
2500
ABORT
Internal system error:
1. Retry the command at one minute intervals a maximum of five times.
1
FAIL
Layer 2 of the primary signaling channel is down:
1. Examine the results of the Primary Signaling Test (#636) and follow 
recommendations provided there.
2. If test #636 passes, the Layer 2 Query test may still fail if the Signaling 
Channel at the far end has not been administered correctly or if the 
Signaling Channel has been busied out. Verify that the Primary Signaling 
Channel (D-channel) at the far end has been administered correctly. Verify 
that the DS1 port used for the Primary D-channel has not been busied out at 
the far end.
2
FAIL
Layer 2 of the secondary signaling channel is down.
1. Examine the results of Secondary Signaling Link Hardware Test (#639) and 
follow recommendations provided there.
2. If tests #639 passes, the Layer 2 Query test may still fail if the Signaling 
Channel at the far end has not been administered correctly or if the 
Signaling Channel has been busied out. Verify that the Secondary Signaling 
Channel (D-channel) at the far end has been administered correctly. Verify 
that the DS1 port used for the Secondary D-channel has not been busied 
out at the far end.