120 Volt Electrical Installation
Always  follow  applicable  local,  state  and  federal 
codes and guidelines.
Use only a dedicated electrical line with a 20-amp 
breaker.
Cord-and-plug  connections  may  not  use  a  cord 
longer than 15 ft (4.6 m) and must be plugged into 
a dedicated 20-amp GFCI connection.  Do not use 
extension cords!
Always use a weatherproof-covered receptacle.
Receptacle shall be located not less than 5 ft (1.5 m) 
from and not exceeding 10 ft (3.0 m) from the inside wall of the spa.
Do not bury the power cord. 
If your cord becomes damaged, replace it before next usage.
All  120V  spas  must  have  a  GFCI.  This  can  be  either  a  20-amp  GFCI 
receptacle or a GFCI cord and plug kit as shown at right (CKIT110 - P/N 
ELE09700086).
Testing the GFCI Breaker
Test  the  GFCI  plug  prior  to  first  use  and  periodically  when  the  spa  is 
powered. To test the GFCI plug version, follow these instructions. (Spa 
should already be plugged in and operational.)
Press the TEST button on the GFCI. The GFCI will trip and the spa will 
1. 
stop operating.
Press the RESET button on the GFCI. The GFCI will reset and the spa 
2. 
will turn back on.
The spa is now safe to use.
If the GFCI trips while the spa is in use, press the RESET button. If the 
GFCI does not reset, unplug the spa and call your local Cal Spas
®
 dealer 
for service. DO NOT USE THE SPA!