Electrical Installation --  Europe
230 Volt Electrical Installation
All 230V spas must be permanently connected (hardwired) to the power 
supply. These instructions describe the only acceptable electrical wiring 
procedure. Spas wired in any other way will void your warranty and may 
result in serious injury.
This is the only acceptable electrical wiring procedure. Spas wired in any 
other way will void your warranty. See the wiring diagram on page 13.
The electrical wiring of this spa must meet the requirements of any applicable 
local, state, and federal codes. The electrical circuit 
must  be  installed  by  an  electrical  contractor  and 
approved by a local building / electrical inspector.
RCD and Wiring Requirements
The power supplied to the spa must be on a dedicated 
RCD  protected  circuit  with  no  other  appliances  or 
lights sharing the power.
Use copper wire with THHN insulation. Do not use 
aluminum wire.
Use  the  table  on  the  next  page  to  determine  your 
GFCI and wiring requirements.
When wires larger than #6 AWG are required, install a junction box near 
the spa and use #6 AWG wire between the junction box and the spa.
Wire runs over 85 feet must increase wire gauge to the next lower number. 
For example: A normal 50 amp RCD with four #8 AWG copper wires run 
over 85 feet would require you to go to four #6 AWG copper wires.