Cal Spas A744L Manuel D’Utilisation

Page de 32
14
Spa Model
GFCI Required Wires Required
Portable Spas
All 230V spas (except 
6205 control boxes 
requiring high amperage 
- see below)
One 32 amp RCD 
or two 16 amp 
RCDs
Four #10 AWG 
copper wires
Spas with the 6300 
control box (when high 
amperage is selected on 
circuit board)
SEE CONFIGURATION 
INSTRUCTIONS ON 
NEXT PAGE.
One 32 amp RCD 
or two 16 amp 
RCDs
Four #10 AWG 
copper wires
Ultimate Fitness Spas
Ultimate Fitness spas 
with one 5.5 kW heater
One 32 amp RCD 
or two 16 amp 
RCDs
Four #10 AWG 
copper wires
Ultimate Fitness spas 
with two 5.5 kW heaters
Service 1: One 32 
amp RCD or two 16 
amp RCDs
Service 1: Four #10 
AWG copper wires
Service 2: One 32 
amp RCD or two 16 
amp RCDs
Service 2: Three #10 
AWG copper wires
In-Ground Spas
Designer in-ground spas 
with one 3 kW heater
One 32 amp RCD 
or two 16 amp 
RCDs
Four #10 AWG 
copper wires
Designer in-ground spa 
with one 3 kW heater 
and one 5.5 kW heater
Service 1: One 32 
amp RCD or two 16 
amp RCDs
Service 1: Four #10 
AWG copper wires
Service 2: One 32 
amp RCD or two 16 
amp RCDs
Service 2: Three #10 
AWG copper wires
Testing the RCD Breaker
Test the RCD breaker prior to first use and periodically when the spa is 
powered. To test the RCD breaker follow these instructions (spa should 
be operating):
Press the TEST button on the RCD. The RCD will trip and the spa will 
1. 
shut off.
Reset the RCD breaker by switching the breaker to the full OFF position, 
2. 
wait a moment, then turn the breaker back on. The spa should have 
power again.