Sony PDW-D1 Manuel D’Utilisation

Page de 60
50
5-3 Details of Functions
  Cha
p
ter
 5
   
Us
in
th
e Ut
ilit
So
ftw
a
re
a) This can be used as a guide in determining 
when to replace parts.
To refresh the display
Click the Refresh button.
Version information
The firmware version information includes 
the following items.
Alarm log
This shows a maximum of 50 alarms 
generated since the unit was last powered 
on.
Select an item in the list to display details of 
that alarm (date and time of generation, and 
location on disc (time code)).
When the limit of 50 items on the list is 
exceeded, older alarms are deleted. 
Powering off the unit deletes all items from 
the list.
Refer to the utility software help for information 
about list of alarms.
5-3-2
Setup Menu
AV settings
Set the following items relating to this unit.
In the Settings column of the table, 
underlined values indicate the factory 
default settings.
Operation 
Hours (r)
Same as Operation 
Hours (resettable
 a)
)
Laser 
Parameter (r)
The cumulative light 
output time for the optical 
head (resettable
 a)
)
Seek 
Running 
Hours (r)
The cumulative seek 
operation time for the 
optical head (unit: hours, 
resettable
 a)
)
Spindle 
Running 
Hours (r)
The cumulative spindle 
rotation time (unit: hours, 
resettable
 a)
)
Loading 
Counter (r)
The total number of times 
disc has been loaded 
(resettable
 a)
)
Item name
Display contents
Package
The package version 
when the firmware was 
downloaded as a 
package
SY
System control software 
version
PIER
”PIER” version of FPGA
CAVE
”CAVE” version of 
FPGA
Drive
Optical disc drive 
system control software 
version
DSP
Audio DSP software 
version
Item name
Display contents
OPERATIONAL FUNCTION
Item name
Settings
PREROLL 
TIME
0 SEC to 5 SEC to 30 
SEC: Set the 
preroll time to 
between 0 and 30 
seconds in steps of 
1 second. A preroll 
time of at least 5 
seconds is 
recommended 
when using this unit 
for editing.