Adaptec MAN-FC2002-001 Manuel D’Utilisation

Page de 110
Installing and Removing an I/O Module/RAID Controller
83
Installing and Removing an I/O Module/RAID Controller
Note: In the following section, “I/O Module” is taken to 
include the RAID Controller in addition to the I/O Module.
The I/O module is located in the rear of the enclosure. 
Follow these procedures to install and remove the I/O 
module.
Installing an I/O 
Module/RAID 
Controller
1
Remove the I/O module blank if there is one installed.
2
Gently insert the I/O module into the slot.
3
Secure in place using the two fixing screws (torque setting 
0.3Nm).
4
Connect the cables as described in Chapter 3.
Removing an I/O 
Module/RAID 
Controller
1
Remove all cables.
2
Loosen the two fixing screws.
3
Using the module handle, gently slide the I/O Module out of the 
slot.
CAUTION: Immediately replace the carrier or install an I/O mod-
ule blank to maintain correct airflow.