Hardware Preparation and Installation
MVME2500 Installation and Use (6806800L01H)
31
4. Install the top and bottom edge of the transition module into the rear guides of the chassis.
5. Ensure that the levers of the two injector/ejectors are in the outward position.
6. Slide the transition module into the chassis until resistance is felt.
7. Move the injector/ejector levers in an inward direction.
8. Verify that the transition module is properly seated and secure it to the chassis using the 
two screws adjacent to the injector/ejector levers.
9. Connect the cables to the transition module.
To remove the transition module from the chassis, reverse the procedure and press the red 
locking tabs (IEEE handles only) to extract the board.
2.5.2
PMC/XMC Support
Installation Procedure
Read all notices and follow these steps to install a PMC on the baseboard.
Damage of Circuits
Electrostatic discharge and incorrect installation and removal can damage circuits or 
shorten its life.
Before touching the board or electronic components, make sure that you are working 
in an ESD-safe environment. 
Product Damage
Inserting or removing modules with power applied may result in damage to module 
components.
Before installing or removing additional devices or modules, read the documentation 
that came with the product.