Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
System Management:
 Vendor Commands
7-33
Disable Payload Control
The Disable Payload Control command disables payload control from the Serial Debug 
interface.
Table 7-29:
Disable Payload Control Command 
 
Reset IPMC
The Reset IPMC command allows the payload to reset the IPMC over the SIPL.
Table 7-30:
Reset IPMC Command 
 
Hang IPMC
The IPMC provides a means to test the watchdog timer support by implementing the Hang 
IPMC command, which simulates firmware hanging by entering an endless loop.
Table 7-31:
Hang IPMC Command 
 
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4
Reset Type Code 
0x00 Cold IPMC reset to the current mode
0x01 Cold IPMC reset to the Normal mode
0x02 Cold IPMC reset to the Standalone mode
0x03 Cold IPMC reset to the Manual Standalone mode 
0x04 Reset the IPMC and enter Upgrade mode
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)