Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
System Management:
 Vendor Commands
7-32
Get Payload Communication Time-Out
The Get Payload Communication Time-Out command reads the payload communication 
time-out value.
Table 7-26:
Get Payload Communication Time-Out Command 
 
Set Payload Communication Time-Out
The Set Payload Communication Time-Out command sets the payload communication 
time-out value.
Table 7-27:
Set Payload Communication Time-Out Command 
 
Enable Payload Control
The Enable Payload Control command enables payload control from the Serial Debug inter-
face.
Table 7-28:
Enable Payload Control Command 
 
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
5
Payload  Time-out
Payload communication time-out measured in hundreds of 
milliseconds. Thus, the payload communication time-out
may vary from 0.1 to 25.5 seconds.
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4
Payload  Time-out
Payload communication time-out measured in hundreds of 
milliseconds. Thus, the payload communication time-out
may vary from 0.1 to 25.5 seconds.
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)