Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
System Management:
 Vendor Commands
7-37
To avoid deadlocks that may occur if the payload software does not respond, the IPMC pro-
vides a special time-out for the payload shutdown sequence. If the payload does not send 
the Graceful Reset command within a definite period of time, the IPMC assumes that the 
payload shutdown sequence is finished, and sends a Module Quiesced Hot Swap event to 
the ATCA-9305 controller.
Table 7-36:
Get Payload Shutdown Time-Out Command 
 
Set Payload Shutdown Time-Out
The Set Payload Shutdown Time-Out command is defined as follows: 
Table 7-37:
Set Payload Shutdown Time-Out Command
 
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
5:6
Time-Out measured in hundreds of milliseconds, LSB first
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4:5
Time-Out measured in hundreds of milliseconds, LSB first
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)