System Management:
 Vendor Commands
7-39
Get Local FRU LED State 
The Get Local FRU LED State command is used to read the local state of a FRU LED.
Table 7-39:
Get Local FRU LED State Command 
 
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4
FRU Device ID
5
LED  ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh reserved (all LEDs under management control are 
addressed)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
5
Local Control LED Function
00h LED is off (default if Local Control not supported)
01h-FAh LED is blinking Off duration specified by this byte, 
on duration specified by byte 5 (in tens of 
milliseconds)
FBh-FEh reserved
FFh LED is on
6
Local Control On Duration 
LED on-time is measured in tens of milliseconds 
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time 
value must be less than 128. Other values when Byte 4=FBh are 
reserved. Otherwise, this field is ignored and shall be set to 0h.
7
Color parameter specifies the color of the LED in the local state for 
multi-color LEDs
8
If the off-first flag parameter is 0, the on part of the blink cycle of 
the LED precedes the off part of the cycle. Otherwise, the off part 
of the blink cycle precedes the on part of the cycle.