Set Local FRU LED State 
The Set Local FRU LED State command is used to change the local state of a FRU LED.
Table 7-38:
Set Local FRU LED State Command 
 
Type:
Byte:
Data Field: 
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4
FRU Device ID
5
LED  ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh Lamp Test (all LEDs under management control are 
addressed)
6
LED Function
00h LED off override
01h-FAh LED blinking override
FBh Lamp Test state Turn on LED specified in byte 3 for the 
duration specified in byte 5, then return to the highest 
priority state.
FCh LED state restored to Local Control state
FDh-FEh reserved
FFh LED on override
7
On  Duration
LED on-time is measured in tens of milliseconds 
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time 
value must be less than 128. Other values when Byte 4=FBh are 
reserved. Otherwise, this field is ignored and shall be set to 0h.
8
Color parameter specifies the color of the LED in the local state for 
multi-color LEDs
9
If the off-first flag parameter is 0, the on part of the blink cycle of 
the LED precedes the off part of the cycle. Otherwise, the off part 
of the blink cycle precedes the on part of the cycle. 
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)