Emerson PMT1 Manuel D’Utilisation

Page de 128
Serial I/O:
 UART Baud Rate Selection
PmT1 and PmE1 User’s Manual
10002367-02
5-6
• frames up to 8-kilobits long
UART BAUD RATE SELECTION
The clock sources for each SCC are defined in the SICR register (FF00,0AEC
16
) and for each 
SMC are defined in the SIMODE register (FF00,0AE0
16
). Any one of four internal baud rate 
generators or an external clock may be used.
The internal baud rate generators are contained in the CPM. They can deliver a maximum 
baud rate at one half of the system clock rate and may be changed on-the-fly. Each baud 
rate generator may be routed to multiple SCCs and SMCs. 
The baud rate produced by a generator is set within the corresponding Baud Rate Generator 
Control (BRGC) register (FF00,09F0 - 9FC
16
). The baud rate is calculated from the system 
frequency (40 MHz) and the values stored in the BRGC register, and depends on whether 
the serial controller is operating in asynchronous or synchronous mode.
The formula for the asynchronous baud rate is:
async baud rate = (system frequency) ÷ ((clock divider +1) x (Div16) x 16)
The clock divider value is stored in bits (12:1) of the BRGC. The Div16 value (1 or 16) is 
selected with bit 0 of the BRGC. 
 lists the clock divider and Div16 values associated 
with typical asynchronous baud rates.
Table 5-4:
Asynchronous Baud Rates (16X oversample)
System Frequency=40 MHz 
Baud 
Rate:
Div16 
Value:
Clock Divider + 1:
Actual Frequency:
Frequency Error 
(%):
50
16
3125
50
0.0
75
16
2083
75
0.0
150
16
1041
150.1
0.0
300
16
521
299.9
0.0
600
1
4167
599.95
0.0
1200
1
2083
1200.2
0.0
2400
1
1042
2399.2
0.0
4800
1
521
4798.5
0.0
9600
1
260
9615.4
0.2
19200
1
130
19230.8
0.2
38400
1
65
38461.5
0.2
57600
1
43
58139.5
0.9
64000
1
39
64102.6
0.2
115200
1
22
113636.4
1.4
56000
1
45
55555.6
0.8