Chapter 4  Configuration 
Installation and Operation Manual 
4-28 
Configuring the Physical Ports
 
ASMi-52 Ver. 2.5 
Configuring the E1 Interface 
The following are commonly used acronyms: 
•  CO – Central Office, where the clock source is set to internal or external 
•  CPE – customer premise equipment. 
When ASMi-52 includes a G.704 E1 port, you can configure the following 
parameters: 
•  Framed mode 
 
Unframed
 – Stream of bits at 2.048 Mbps 
 
G732N
 – Timeslot 0 contains sync word  
 
G732S transparent
 – 16 frames per multi-frame, timeslot 16 is passed 
transparently. 
 
•  If the opposite modem is E1, then the Framed Mode value can be is G732N, 
G732S Transparent, or Unframed. 
•  If the opposite modem is Serial DTE or LAN, then the Framed Mode value can 
be G732N, or Unframed 
•  If Frame Mode is Unframed, then all the rest of the parameters are disabled. 
 
•  Sync mode: define the time required for the E1 port to return to normal 
operation after sync loss: 
 
CCITT
 – As per requirements of ITU-T Rec.G.732 
 
Fast
 – After 1 sec 
 
62411
 – As per requirements of AT&T TR-62411 (after 10 sec). 
•  CRC-4: Enabling generation and checking of check bits for the frames 
transmitted on the E1 port (as per CRC-4 polynomial specified by ITU G.704). 
Check bits generation is available only for the G732N framing mode. 
•  Idle Code: Selecting a code transmitted to fill unused timeslots in the E1 
frames. 
•  Time Slot Assignment – Assigning each timeslot to carry user’s data 
•  Unit Identical Set 
 
Yes
 – copies Sync Mode, Time Slot Assignment and Idle Code definitions to 
the remote modem 
 
No
 – Sync Mode, Time Slot Assignment and Idle Code must be defined in 
both modems individually 
•  First time slot for remote E1 – define the first time slot for the remote E1 unit. 
The E1 port configuration is performed via the E1 Configuration menu. 
 
To access the E1 Port Configuration menu: 
1.  From the E1 Configuration menu, select E1 Local Port/E1 Remote Port (Main 
menu > Configuration > E1 Configuration > E1 Local Port/E1 Remote Port). 
The E1 Local Port/E1 Remote Port menu appears (see 
Figure 4-32
 and 
Figure 4-33
). 
Note