Chapter 4  Configuration 
Installation and Operation Manual 
4-30 
Configuring the Physical Ports
 
ASMi-52 Ver. 2.5 
ASMi-52 
Framed mode (Unframed) 
1. Unframed 
2. G732N 
3. G732S transparent 
>  
 
ESC-prev. menu; !-main menu; &-exit; @-scroll 
Figure 4-34.  Framed Mode Menu 
Enabling CRC-4 Code Generation 
You have to enable the CRC-4 code generation if you intend to gather statistics on 
the E1 performance. CRC-4 code generation is available for ASMi-52 units 
configured to G732N framing mode. 
 
•  CRC-4 code generation is configurable if one of the conditions below is fulfilled. 
If the local ASMi-52 is configured as a CO, 
if the local ASMi-52 is configured as CPE and the remote is not an E1 modem. 
•  The remote ASMi-52 is configurable if the local is configured as CO and is not an 
E1 modem. 
 
 
To enable CRC-4 code generation: 
1.  From the E1 Local Port menu, select CRC-4 (Main menu > Configuration > 
E1 Configuration > E1 Local Port > CRC-4). 
The CRC-4 value changes. 
2.  Save the changes. 
Setting the Sync Mode 
You can define the time required for the E1 port operating in framed mode to 
resume normal operation after loss of synchronization: 
•  CCITT – As per requirements of ITU-T Rec.G.732 
•  Fast – After 1 sec 
•  62411 – As per requirements of AT&T TR-62411 (after 10 sec). 
 
To select resynchronization time: 
1.  From the E1 Local Port/T1 Local Port menu, select Sync Mode (Main menu > 
Configuration > E1 Configuration/T1 Configuration > E1 Local Port > Sync 
Mode). 
The Sync Mode menu appears (see 
Figure 4-35
). 
2.  From the Sync Mode menu, select CCITT, FAST, or 62411
The E1 Local Port menu appears. 
3.  Save the changes. 
Note