RAD Data comm ASMi-52 Manuel D’Utilisation

Page de 186
Installation and Operation Manual 
Chapter 4  Configuration 
ASMi-52 Ver. 2.5 
Configuring the Physical Ports 
4-29 
ASMi-52 
E1 Local Port 
1. Framed mode 
(G732N) 
2. Sync mode 
(CCITT(complies with G732)) 
3. CRC-4 
 
(NO) 
4. Idle code 
(ff) 
5. Time slots assign  
6. Unit Identical Set 
(Yes) 
7. Number TS for remote E1 
8. Save 
 
>  
 
ESC-prev. menu; !-main menu; &-exit; @-scroll 
Figure 4-32.  E1 Local Port Menu 
ASMi-52 
E1 Remote Port 
Framed mode 
(G732N) 
Sync mode 
(CCITT (complies with G732)) 
CRC-4  (NO) 
Idle code 
(ff) 
1. Time slots assign  
2. Save 
 
>  
 
ESC-prev. menu; !-main menu; &-exit; @-scroll 
Figure 4-33.  E1 Remote Port Menu 
Selecting E1 Framing Mode 
 
•  The Framing mode is configurable if one of the conditions below is fulfilled. 
If the local ASMi-52 is configured as CO, 
if the local ASMi-52 is configured as CPE and the remote is not an E1 modem. 
•  The remote ASMi-52 is configurable if the local is configured as CO and is not an 
E1 modem 
•  If Frame Mode is Unframed, then the remaining E1 parameters are disabled. 
 
 
To select E1 framing mode: 
1.  From the E1 Local Port menu, select Framed Mode (Main menu > 
Configuration > E1 Configuration > E1 Local Port > Framed Mode). 
The Framed Mode menu appears (see 
Figure 4-34
). 
2.  From the Framed Mode menu, select UnframedG732N, or G732S 
transparent
The E1 Local Port menu appears. 
3.  Save the changes. 