Chapter 2  Installation 
IPmux-16 Installation and Operation Manual 
2-4  Installation and Setup
 
 
2.5  Installation and Setup 
Setting Jumpers 
IPmux-16 internal jumpers and switches do not need to be configured by the user 
and therefore removing the product cover is not required. 
Connecting Interfaces and Cables 
Figure 2-2 and Figure 2-3 illustrate the rear and front panel options available for  
IPmux-16. 
 
Figure 2-2.  IPmux-16 Front Panel 
 
PS2
PS1
~100-240VAC     3A T 125V
~100-240VAC     3A T 125V
ALARMS
POWER
POWER
O
O
I
I
EXT. CLK
 
Figure 2-3.  IPmux-16 Rear Panel 
Grounding 
Interrupting the protective grounding conductor (inside or outside the instrument) 
or disconnecting the protective earth terminal can make this instrument 
dangerous. Intentional interruption is prohibited. 
 
 
Before switching ON this instrument and before connecting any other cable, 
the protective earth terminals of this instrument must be connected to the 
protective ground conductor of the power cord. 
 
 
Fuses 
Make sure that only fuses with the required rated current and specified type,  
2 A T 250V as marked on the IPmux-16 rear panel, are used for replacement. 
Whenever it is likely that the protection offered by fuses has been impaired, the 
instrument must be made inoperative and be secured to prevent any operation. 
Warning