Chapter 2 Installation
Installation and Setup
2-5
Location of Connectors
• Connect the E1/T1 and Ethernet ports according to the appropriate pinout.
Interface connections are made from the IPmux-16 front panel from each
module, as shown in Figure 2-3. The connectors required for each interface
module, as shown in Figure 2-3. The connectors required for each interface
are listed in Section 2.4. E1/T1 port pinouts are listed in Table 2-2, Ethernet
port pinouts are listed Table 2-3.
port pinouts are listed Table 2-3.
Table 2-2. E1/T1 Port Connectors Pinout
Pin Designation Direction
Function
1
RD (R)
Input
Receive data (ring)
2
RD (T)
Input
Receive data (tip)
3,6 –
–
FGND
4
TD (R)
Output
Transmit data (ring)
5
TD (T)
Output
Transmit data (tip)
7,8 –
N/A
Not
connected
Table 2-3. Ethernet Port Pinout
Pin #
Pinout
1 Tx+
2 Tx–
3 Rx+
4, 5, 7, 8
–
6 Rx–
Connecting the Control Port
➤
To connect the Control Port:
The Control port is located on the right side of the IPmux-16 front panel (see
Figure 2-3).
• Connect the RS-232/V.24, DB-9 DTE connector cable, supplied with
The Control port is located on the right side of the IPmux-16 front panel (see
Figure 2-3).
• Connect the RS-232/V.24, DB-9 DTE connector cable, supplied with
IPmux-16, to the IPmux and then to the DTE. The control port is DTE for an
ASCII terminal.
ASCII terminal.
Connecting the Alarm Connector
An Alarms connector is located on the rear panel. A DB-9 female connector
provides alarm relay dry-contacts to external supervisory equipment (for future
use). This feature allows IPmux-16 to send alarms on its dry contact port. A single
use). This feature allows IPmux-16 to send alarms on its dry contact port. A single
output pin indicates an IPmux-16 alarm.