Chapter 2  Installation 
 
Installation and Setup 
2-5 
Location of Connectors 
•  Connect the E1/T1 and Ethernet ports according to the appropriate pinout. 
Interface connections are made from the IPmux-16 front panel from each 
module, as shown in Figure 2-3. The connectors required for each interface 
are listed in Section 2.4. E1/T1 port pinouts are listed in Table 2-2, Ethernet 
port pinouts are listed Table 2-3
Table 2-2.  E1/T1 Port Connectors Pinout 
Pin Designation Direction 
Function 
RD (R) 
Input 
Receive data (ring) 
RD (T) 
Input 
Receive data (tip) 
3,6 – 
– 
FGND 
TD (R) 
Output 
Transmit data (ring) 
TD (T) 
Output 
Transmit data (tip) 
7,8 – 
N/A 
Not 
connected 
Table 2-3.  Ethernet Port Pinout  
Pin # 
Pinout 
1 Tx+ 
2 Tx– 
3 Rx+ 
4, 5, 7, 8 
– 
6 Rx– 
Connecting the Control Port 
➤ 
To connect the Control Port: 
The Control port is located on the right side of the IPmux-16 front panel (see 
Figure 2-3). 
•  Connect the RS-232/V.24, DB-9 DTE connector cable, supplied with  
IPmux-16, to the IPmux and then to the DTE. The control port is DTE for an 
ASCII terminal. 
Connecting the Alarm Connector 
An Alarms connector is located on the rear panel. A DB-9 female connector 
provides alarm relay dry-contacts to external supervisory equipment (for future 
use). This feature allows IPmux-16 to send alarms on its dry contact port. A single 
output pin indicates an IPmux-16 alarm.