   Setup
Rev. B
❏ Label Settings
In "Label Settings", select the maximum length for automatic paper measurement, and then 
choose whether with or without the function of feeding paper to the print starting position at 
power on.
Maximum length of automatic paper measurement
Select the maximum length of automatic paper measurement. Match the maximum length of 
the auto-measurement with the black mark spacing of the paper used.
With or without the function of feeding paper to the print starting position at power on
Press the FEED button the number of times required to select whether with or without the 
function of feeding paper to the print starting position at power on.
Setting Various Items via Utilities
Besides the items that can be set in the memory switch setting mode, you can set a variety of 
items using the utility software for TM series printers provided by Epson. The utilities are 
explained in “Various Utilities” on page 4-7. For details, refer to the relevant materials.
How to Set Various Items with ESC/POS Commands
Besides the items that can be set in the memory switch setting mode, you can set a variety of 
items using the ESC/POS commands. The ESC/POS commands are explained in “Introduction 
of Control Methods” on page 4-1. (For details, refer to “
Error code” on page F-3.)
Press FEED button
Selected maximum length for automatic paper 
measurement
0 times:
No change
1 time:
160mm
2 times:
300mm
3 or more times:
No change
Press FEED button
Selected paper
0 times:
No change
1 time:
Feeding paper to print starting position is executed 
at power-on
2 times:
Feeding paper to print starting position is not 
executed at power-on
3 or more times:
No change