Epson L90 Manuel D’Utilisation

Page de 192
Rev. B
Setup   2-35
TM-L90/TM-L90 with Peeler Technical Reference Guide
2.9  Memory Switch Functions
This printer has the following software switches, called memory switches, in the non-volatile 
memory.
Msw 1, Msw 2, Msw 8
Customized values
Serial communication conditions
These settings can be made by the memory switch setup utility (see page 4-7) or ESC/POS 
commands. Refer to the “ESC/POS Application Programming Guide” for details of the 
commands.
2.9.1  TM-L90 memory switch settings
Some settings of Msw 2 and Msw 8 can be made in the memory switch setting mode. (See page 
2-27
)
Msw 1-7, 1-8 are effective only when serial interface is used.
*: Factory setting
*: Factory setting
MSW1
Bit
Function
0 (OFF)
1 (ON)
1
Send power on notification
Not sent *
Sent
2
Select receive buffer capacity
Large (4K bytes) *
Small (45 bytes)
3
Conditions for Busy status
Receive buffer full or 
offline *
Receive buffer full
4
Data processing when reception error occurs
Substitute with "?" *
Ignored
5
Automatic line feed
Invalid *
Valid
6
Reserved
Fixed *
7
#6 pin: Select reset signal
Not used *
Used
8
#25 pin: Select reset signal
Not used *
Used
MSW2
Bit
Function
0 (OFF)
1 (ON)
1
Reserved
--
Fixed to 1 (ON) (do not 
change setting) *
2
Autocutter operation
Disabled
Enabled *
3-8
Reserved
Fixed to OFF
--