SEQUENCE OF OPERATIONS 1042 / 1043 / 1242 / 1243 
MODEL 1042 - 240V - 50HZ - NATURAL GAS 
MODEL 1043 - 240V - 50HZ - L.P. GAS 
MODEL 1242 - 240V - 50HZ - NATURAL GAS/DUAL BELT 
MODEL 1243 - 240V - 50HZ - L.P.GAS/DUAL BELT 
 
POWER SUPPLY 
Electrical Power to be supplied to the Oven by a three conductor service. 
Black conductor is Hot 
Red conductor is Neutral 
Green conductor is Ground 
CONTROL BOX AUTO 
COOL DOWN 
When the temperature in the Control Box reaches 120°F + 3°, the Cooling Fan 
Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will 
interrupt power to the Cooling Fan when the Control Box temperature falls to 100°F + 
3°. 
MAIN FAN CIRCUIT 
Electrical power is permanently supplied to the normally open contacts of the Double 
Pole Main Fan Relay, the Cooling Fan Thermostat, the normally open Double Pole 
Main Fan Switch, and the normally open Cool Down Thermostat (thermostat closes 
at 160°F and opens at 140°F). Closing the Main Fan Switch supplies 240 VAC 
through a 3A Fuse to the primary of the control circuit Step Down Transformer. The 
Transformer steps the voltage down to 120 VAC for the control circuit. 120 VAC is 
supplied to the coil of the Double Pole Main Fan Relay. The coil of the relay is 
energized. The normally open contacts now close, energizing the Main Fan Motor 
through one 10A Fuse. Closing the Fan Switch also supplies power to the Cooling 
Fan, the 12.6 VAC Transformer the Burner and Conveyor Switches. 
TRANSFORMER (12.6 
VAC) 
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC 
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to 
14 VAC) with a center tap, and supplies power to the Time/Temp Display. The 
voltage from each leg of the Transformer's secondary to the center tap should be 
one half of the secondary voltage. 
BURNER CIRCUIT 
Closing the Fan Switch and the normally open Burner Switch supplies 120 VAC 
through the Air Pressure Switch, to the Temperature Control Board, the normally 
open contacts of the Burner Motor Relay (Burner Motor Relay discontinued after S/N 
14791) and the primary of the 24 VAC Transformer. The transformer's secondary 
supplies 24 VAC to the burner motor relay coil (the normally open contacts close 
within 30 seconds), and the normally open Centrifugal Switch. When the relay 
contacts close, the Burner Blower Motor is energized. As this motor reaches approx. 
1,600 R.P.M its internal centrifugal switch closes, supplying 24 VAC to the Gas 
Control Valve. When the Gas Control Valve is supplied with 24 VAC, the pilot valve 
is energized, and the igniter circuit is energized. Ignition should now occur. After pilot 
flame is proven, the Main Gas Valve is energized. The Burner Indicator Light is also 
energized. 
TEMPERATURE 
CONTROL 
 
 
 
 
CONVEYOR DRIVE 
(S/N Q14790 & Below, 
1200 series 
 S/N Q14973 & Below, 
1000 series)  
 
(S/N Q14791 & Above, 
1200 series  
S/N Q14974 & Above, 
1000 series refer to 
Pg. 9) 
Closing the Fan Switch and Burner Switch supplies 120 VAC to the Temperature 
Control Board. The 1K or 1000 ohm Temperature Potentiometer is adjusted to 
desired temperature. The Thermocouple will provide varying millivolts to the 
Temperature Controller. The Temperature Controller supplies 120 VAC to the 
Solenoid Valve at intermittent intervals to maintain desired temperature. 
Closing the fan switch and the normally open conveyor switch supplies 120 VAC to 
the Motor Control Board. AC volts are converted to DC volts and are supplied to the 
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control 
Potentiometer (5,000 ohm 10 turn ) will change resistance at terminals P1, P2, and 
P3 varying the DC voltage to the motor. The speed of the conveyor motor will 
increase or decrease as the DC voltage from the board increases or decreases 
respectively. As the motor turns, it drives both the reducer gearbox and the tach. 
generator. The tach. generator is a DC voltage generator which supplies a voltage to 
the DC motor control board and is used as a reference for maintaining a constant 
conveyor speed.