Impinger I -–1000 Series Service Manual - International 
CONVEYOR DRIVE 
(S/N 100 to 4389) 
Closing the Fan Switch and the normally open Conveyor Switch supplies 120 VAC 
through a 3A Fuse, to the Motor Control Board. AC volts are converted to D.C. volts 
and are supplied to the Conveyor Motor at board terminals A1 and A2 through a 
D.P.D.T. Reversing Switch. Adjustment of the Speed Control Potentiometer (500 
ohm, 10 turn) will change resistance at terminals S1, S2, and S3 varying the D.C. 
voltage to the Conveyor Motor. The speed of the Conveyor Motor will increase or 
decrease as the D.C. voltage from the Motor Control Board increases or decreases 
respectively. 
(S/N 4390 and UP 
1000 Series) 
 (S/N 4390 to 14790 
1200 Series)  
 
 
(S/N 14791 & Above 
1200 Series  
See Page 9 
Closing the fan switch and the normally open Conveyor switch supplies 120 VAC to 
the Motor Control Board. AC volts are converted to DC volts and are supplied to the 
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control 
Potentiometer (5,000 ohm 10 turn ) will change resistance at terminals P1, P2, and 
P3 varying the DC voltage to the motor. The speed of the conveyor motor will 
increase or decrease as the DC voltage from the board increases or decreases 
respectively. As the motor turns, it drives both the reducer gearbox and the tach. 
generator. The tach. generator is a DC voltage generator which supplies a voltage to 
the DC motor control board and is used as a reference for maintaining a constant 
conveyor speed. 
NOTE 
The 1200 Series Ovens utilize 2 complete conveyor drive systems. 
TIME TEMP 
DISPLAY(S/N 4390 & 
Above1000 Series) S/N 
4390-147901200 Series) 
 
 
 (T/T Display S/N 
Q14791& Above1200 
Series See Page 9 
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 
VAC to the primary of the 12.6 volt Transformer. The secondary output of the 
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is 
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is 
terminal 2. The display works on a balanced input and center tap voltage to each leg 
must be 1/2 the total reading. 
The speed side of the Time/Temp. Display uses a slotted.disc (cemented to tach. 
coupling) to break the infra-red light beam of the optical switch (mounted on gear 
motor) producing electrical pulses that are transmitted to the display. The display 
converts these pulses into a read-out of minutes and seconds. 
The temperature portion of the display uses a Thermistor Probe to sense oven 
temperature. The thermistor outputs a resistance proportional to the oven 
temperature. This resistance is then converted by the display into a temperature 
reading. 
NOTE 
The 1200 Series Ovens use a Double Pole Double Throw Switch to connect the two 
Optical Encoder Assemblies to the Time/Temp. Display. By activating the switch, 
either the front or rear belt speed can be shown by the Time/Temp. Display. 
SEQUENCE OF OPERATIONS 1030 
MODEL 1030 - 220 VAC - 50HZ - 1 PHASE 
 
POWER SUPPLY 
Electrical Power to be supplied to the Oven by a three conductor service. 
Black conductor is Hot 
Red conductor is Neutra 
Green conductor is Ground 
CONTROL BOX  
AUTO COOL DOWN 
When the temperature in the Control Box reaches 120°F + 3°, the Cooling Fan 
Thermostat will switch power to the Control Box Cooling Fan. The Thermostat will 
interrupt power to the Cooling Fan when the Control Box temperature falls to 100°F + 
3°. 
MAIN FAN CIRCUIT 
Electrical power is permanently supplied to the normally open contacts of the Double 
Pole Main Fan Relay, the Cooling Fan Thermostat, the normally open Main Fan 
Switch, and the normally open Cool Down Thermostat (thermostat closes at 160°F 
and opens at 140°F). Closing the Main Fan Switch supplies 220 VAC through a 3A 
Fuse to the (normally open) Burner Switch, and to the control circuit Step Down 
Transformer (the transformer steps the voltage down to 120 VAC for the control 
circuit) 120 VAC is supplied to the coil of the Main Fan Relay The coil is energized, 
the normally open contacts close, supplying 220 VAC through one 10A Fuse to the 
Main Fan Motor. 120 VAC is also supplied to the 12.6 VAC Transformer, the 
Temperature Controller and the Conveyor Switch. 
TRANSFORMER (12.6 
VAC) 
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC 
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to