14 VAC) with a center tap, and supplies power to the Time/Temp Display. The 
voltage from each leg of the Transformer's secondary to the center tap should be 
one half of the secondary voltage 
BURNER CIRCUIT 
Closing the normally open Burner Switch supplies 220 VAC, through the gas 
pressure-proving switch, and through the Main Fan Air Pressure Switch, to the 
Ignition Control. The combustion motor relay is energized, its normally open contacts 
now close, supplying120 VAC to the combustion motor. The normally open 
combustion air switch closes upon sensing air. After pre-purge period of between 30 
and 60 seconds, the Ignition Transformer is energized and the Main Gas Valve is 
energized. Ignition should now occur. 
TEMPERATURE 
CONTROL 
Closing the Fan Switch
 
supplies (through the Step down Transformer) 120 VAC to 
the Temperature Control Board. The 2.5K ohm Temperature Potentiometer is 
adjusted to desired temperature. The Thermocouple will provide varying millivolts to 
the Temperature Controller. The Temperature Controller supplies 120 VAC to the 
Solenoid Valve at intermittent intervals to maintain desired temperature. 
CONVEYOR DRIVE 
(S/N4390-Q17170)  
 
 
 
 
 
(Conveyor Drive 
Q171701 & Above See 
Page 9) 
Closing the fan switch and the normally open conveyor switch supplies 120 VAC to 
the Motor Control Board. AC volts are converted to DC volts and are supplied to the 
Conveyor Motor at terminals A+ and A-. Adjustment of the Speed Control 
Potentiometer (5,000 ohm 10 turn) will change resistance at terminals P1, P2, and 
P3 varying the DC voltage to the Conveyor Motor. The speed of the conveyor motor 
will increase or decrease as the DC voltage from the board increases or decreases 
respectively. As the motor turns, it drives both the reducer gearbox and the tach. 
generator. The tach. generator is a DC voltage generator which supplies a voltage to 
the DC motor control board and is used as a reference for maintaining a constant 
conveyor speed. 
(Time/Temp Display 
Q17171 & Above See 
Page 9) 
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 
VAC to the primary of the 12.6 volt Transformer. The secondary output of the 
transformer, normally 13 to 14 VAC (depending on input), with a center tap, is 
supplied to terminals 1,2, and 3 of the Time/Temp. Display. The center tap is 
terminal 2. The display works on a balanced input and center tap voltage to each leg 
must be 1/2 the total reading. 
TIME/TEMP 
DISPLAY(Q17171 & 
Above See Page 9 
The speed side of the Time Temp. Display uses a slotted disc (cemented to tach. 
coupling) to break the infra-red light beam of the optical switch (mounted on gear 
motor) producing electrical pulses that are transmitted to the display. The display 
converts these pulses into a read-out of minutes and seconds. 
The temperature portion of the display uses a Thermistor Probe to sense oven 
temperature. The thermistor outputs a resistance proportional to the oven 
temperature. This resistance is then converted by the display into a temperature 
reading. 
 
SEQUENCE OF OPERTIONS 1032 
 
MODEL 1032 - 380Y/220 VAC - 50 HZ - 3 PHASE 
 
POWER SUPPLY 
Electrical Power to be supplied to the Oven by a five conductor service 
Black conductor is Hot 
Red conductor is Hot 
Orange conductor is Hot 
White conductor is Dedicated Neutral 
Green conductor is Ground 
MAIN FAN CIRCUIT 
Electrical power is permanently supplied through 3, 50A fuses to the normally open 
contacts of the Mercury Contactor. Power is also supplied through one 10A fuse to 
the normally open contact of the Main Fan Relay, through a 1A Fuse to the normally 
open Double Pole Main Fan Switch, and to the normally open Cool-Down 
Thermostat (thermostat closes at 160°F and opens at 140°F.) Closing the Main Fan 
Switch supplies 220VAC to the primary of the control circuit Step Down Transformer. 
(The transformer steps the voltage down to 120 VAC for the control circuit.) 120 VAC 
is supplied to the coil of the Main Fan Relay. The coil of the relay is energized, the 
normally open contacts close, energizing the Main Fan Motor. Closing the Main Fan 
Switch also supplies power to the 12.6 VAC Transformer, the Control Box Cooling