TRIGger:PULSe Subsystem
TVS600 & TVS600A Command Reference
2–271
TRIGger:PULSe:GLITch:POLarity
TRIGger:PULSe:GLITch:POLarity?
TRIGger:PULSe:GLITch:POLarity?
Sets or queries the polarity of the event pulse for pulse glitch triggering. Before
this command will be effective, you must set TRIGger:TYPE to PULSe and
TRIGger:PULSe:CLASs to GLITch. Refer to the discussion of TRIG-
ger:PULSe:CLASs on page 2–270.
this command will be effective, you must set TRIGger:TYPE to PULSe and
TRIGger:PULSe:CLASs to GLITch. Refer to the discussion of TRIG-
ger:PULSe:CLASs on page 2–270.
TRIGger[:A]:PULSe:GLITch:POLarity <polarity>
TRIGger[:A]:PULSe:GLITch:POLarity?
<polarity>
Query response
EITHer
NEGative
POSitive
NEGative
POSitive
EITH
NEG
POS
NEG
POS
POS
Execution Error –224, “Illegal parameter value”
Attempted to set polarity to an illegal value.
Attempted to set polarity to an illegal value.
None
Command:
TRIG:PULS:GLIT:POL NEG
Query:
TRIG:PULS:GLIT:POL?
Response:
NEG