Regency IG34 Gas Inbuilt Fireplace
AERATION SETTINGS
The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by 
the installer.  (Close the aeration for a more yellow fl ame, or open it to make the fl ame bluer). 
 NG:  13mm 
open
 LPG: 13mm 
open
 ULPG: 
13mm 
open
Note:   Any damage due to carboning resulting from improperly setting the aeration and restrictor setting controls is NOT covered 
under warranty.
INSTALLATION
IG34-NG: For 0 to 610 meters altitude
IG34-LPG: For 0 to 610 meters altitude
IG34-ULPG: For 0 to 610 meters altitude
Burner Inlet Orifi ce Sizes:
                  NG 
       LPG        ULPG
Burner  
 #37 
       #52          #53
 
            
Max. Input 
 NG 
31.7 
mj 
 LPG 
30.6 
mj
 ULPG 
26.4 
mj
Min. Input 
 NG 
21.1 
mj
 LPG 
25.1 
mj
 ULPG 
20.9 
mj
  
Supply Pressure   
 NG 
1.13 
kPa
 LPG 
2.75 
kPa
 ULPG 
2.75 
kPa
Manifold Pressure    HIGH            LOW
 
NG 
0.87 kPa         0.4kPa
 
LPG 
2.51 kPa        1.6kPa
 
ULPG 
2.51 kPa        1.6kPa  
Electrical: 240 V. 50Hz.
Circulation: High/Off/LO speed fan,
 
            150/89 CFM.
Log Set: Ceramic fi ber, 7 per set.
Aeration Setting
NG 
     13mm open 
LPG        13mm open
ULPG      13mm open
 
        
System Data
IG34