3com S7906E Guide De Référence

Page de 2327
 
1-14 
Parameters 
freq-sec: Frequency with which the system saves the log file, in the range 1 to 86,400 seconds. The 
default value is 86,400. 
Description 
Use the info-center logfile frequency command to configure the frequency with which the system 
saves the log file. 
Use the undo info-center logfile frequency command to restore the default frequency. 
Examples 
# Configure the frequency with which the system saves the log file as 60,000 seconds. 
<Sysname> system-view 
[Sysname] info-center logfile frequency 60000 
info-center logfile size-quota 
Syntax 
info-center logfile size-quota size 
undo info-center logfile size-quota 
View 
System view 
Default Level 
2: System level 
Parameters 
size: The maximum capacity of a disk, in MB. The value, however, cannot be smaller than 1 MB and 
larger than 10 MB. The default value is 1. 
Description 
Use the info-center logfile size-quota command to set the maximum storage space reserved for a log 
file. 
Use the undo info-center logfile size-quota command to restore the default maximum storage space 
reserved for a log file. 
Examples 
# Set the maximum storage space reserved for a log file to 6 MB. 
<Sysname> system-view 
[Sysname] info-center logfile size-quota 6 
info-center logfile switch-directory 
Syntax 
info-center logfile switch-directory dir-name