3com S7906E Guide De Référence
1-15
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the display poe-power ac-input state command to display the state information of the AC input
power.
Examples
# Display the state information of the AC input power.
<Sysname> display poe-power ac-input state
Module Number : 2
Output AC Current A Alarm : Normal
Output AC Current B Alarm : Under Limit
Output AC Current C Alarm : Lack Phase
Module 1:
Volt Phase AB Alarm : Above Limit
Volt Phase BC Alarm : Fuse Broken
Volt Phase CA Alarm : Switch Off
Module 2:
Volt Phase AB Alarm : Above Limit
Volt Phase BC Alarm : Fuse Broken
Volt Phase CA Alarm : Switch Off
Table 1-10 display poe-power ac-input state command output description
Field
Description
Module Number
Number of modules that a power supply unit (PSU) contains
Output AC Current A/B/C Alarm
Output three-phase AC voltage state:
z
Normal: The voltage is normal.
z
Under Limit: The voltage is below the lower limit.
z
Above Limit: The voltage is above the upper limit.
z
Lack Phase: A phase is lost.
z
Fuse Broken: The fuse is broken.
z
Switch Off: The switch is turned off.
z
Other Error: Other faults
Volt Phase AB/BC/CA Alarm
AC voltage input state: Same as those of the output
three-phase AC current
three-phase AC current