3com S7906E Guide De Référence

Page de 2327
 
1-15 
View 
Any view 
Default Level 
1: Monitor level 
Parameters 
None 
Description 
Use the display poe-power ac-input state command to display the state information of the AC input 
power. 
Examples 
# Display the state information of the AC input power. 
<Sysname> display poe-power ac-input state 
Module  Number                 :  2 
Output AC Current A Alarm   : Normal 
Output AC Current B Alarm   : Under Limit 
Output AC Current C Alarm   : Lack Phase 
Module 1: 
    Volt  Phase  AB  Alarm      :  Above  Limit 
    Volt  Phase  BC  Alarm      :  Fuse  Broken 
    Volt  Phase  CA  Alarm      :  Switch  Off 
Module 2: 
    Volt  Phase  AB  Alarm      :  Above  Limit 
    Volt  Phase  BC  Alarm      :  Fuse  Broken 
    Volt  Phase  CA  Alarm      :  Switch  Off 
Table 1-10 display poe-power ac-input state command output description 
Field 
Description 
Module Number 
Number of modules that a power supply unit (PSU) contains
Output AC Current A/B/C Alarm 
Output three-phase AC voltage state: 
Normal: The voltage is normal. 
Under Limit: The voltage is below the lower limit. 
Above Limit: The voltage is above the upper limit. 
Lack Phase: A phase is lost. 
Fuse Broken: The fuse is broken. 
Switch Off: The switch is turned off. 
Other Error: Other faults 
Volt Phase AB/BC/CA Alarm 
AC voltage input state: Same as those of the output 
three-phase AC current